Vermont Castings Radiance RADVTVG Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Öfen Vermont Castings Radiance RADVTVG herunter. Vermont Castings Radiance RADVTVG Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 52
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
INSTALLER / CONSUMER
SAFETY INFORMATION
20012697 1/08 Rev. 3
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer,
service agency or the gas suppler.
WHAT TO DO IF
YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from your neighbors phone. Follow
the gas suppliers instructions.
If you cannot reach your gas supplier,
call the fire department.
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.
This appliance may be installed in an
after market permanently located
manufactured (mobile) home where not
prohibited by local codes.
This appliance is only for use with the
type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases unless a certified kit is
used.
Radiance
Direct Vent Gas Heater
Models:
RADVT Series: RADVTCB, RADVTEB, RADVTMB,
RADVTBS, RADVTCH, RADVTVG, RADVTBD, RAD-
VTBB, RADVTCG, RADVTGG, RADVTSG,
RADVTC Series: RADVTCCB, RADVTCEB,
RADVTCMB, RADVTCBS, RADVTCCH, RADVTCVG,
RADVTCBD, RADVTCBB, RADVTCCG, RADVTCSG
Homeowners Installation
and Operating Manual
CE RTI FIE D
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
12697
Radiance cover
7/07
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Seitenansicht 0
1 2 3 4 5 6 ... 51 52

Inhaltsverzeichnis

Seite 1 - Direct Vent Gas Heater

INSTALLER / CONSUMER SAFETY INFORMATION20012697 1/08 Rev. 3PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE.WARNING!IF THE INFORMATION

Seite 2 - Table of Contents

1010Radiance Direct Vent Gas Heater 20012697Vent Termination ClearancesYour stove is approved to be vented either through the side wall, or vertical t

Seite 3 - 20012697

11Radiance Direct Vent Gas Heater20012697VVVVVVVXXXDEBBBCBMBAJKFLVENT TERMINATION AIR SUPPLY INLETAREA WHERE TERMINAL IS NOT PERMITTEDHIOp

Seite 4

1212Radiance Direct Vent Gas Heater 20012697Fig. 12 Termination clearances.Outside CornerInside CornerTermination ClearancesTermination clearances fo

Seite 5

13Radiance Direct Vent Gas Heater20012697Venting Requirements and OptionsApproved Vent System ComponentsThe Radiance Heater must be vented to the outd

Seite 6 - Installation Requirements

1414Radiance Direct Vent Gas Heater 20012697Vertical Termination Cap 4DT-VCCFM Vent ComponentsThe following kits are available to meet the needs of m

Seite 7 - 

15Radiance Direct Vent Gas Heater20012697ST720Radianceslide stove back7/30/02 djtST720Fig. 13 Slide stove back just far enough to access rear leg ho

Seite 8 - Horizontal

1616Radiance Direct Vent Gas Heater 20012697ST347aJUVFK28 rheostat install9/21/00Rheostat Retaining CollarRheostat KnobST347aFig. 18 Attach the fan r

Seite 9 - 12/3/99 djt

17Radiance Direct Vent Gas Heater20012697Venting System AssemblyGeneral InformationThe Radiance is approved for installation only with the vent compon

Seite 10 - IMPORTANT

1818Radiance Direct Vent Gas Heater 20012697ST651Fig. 23 Simpson Dura-Vent - install outer adapter pipe. ST652dura ventattach outer assy4/20/01

Seite 11 - meet these requirements

19Radiance Direct Vent Gas Heater200126974. For CFM Vent Pipe only: If necessary, measure to determine the vertical length (X) of pipe required from

Seite 12 - Termination Clearances

22Radiance Direct Vent Gas Heater 20012697PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.Thank you and congratulatio

Seite 13 - Simpson DuraVent Components

2020Radiance Direct Vent Gas Heater 2001269711. For CFM only: Install Charcoal Gray Pipe Rings (#7FSDRG) or Polished Brass Pipe Rings (#7FSDRP) at pip

Seite 14 - CFM Vent Components

21Radiance Direct Vent Gas Heater200126977. Install the appropriate roof support and flashing, making certain that the upper flange of the flashing base

Seite 15 - Assembly Procedures

2222Radiance Direct Vent Gas Heater 20012697GasketLock TabInlet EndOutlet EndST922To Termination To ApplianceFig. 34 Joint conne

Seite 16 - Fig. 16 Remove rear shroud

23Radiance Direct Vent Gas Heater20012697The Cathedral Ceiling Support (CCS) may be used in pitched or flat ceiling installations and comes with a supp

Seite 17 - General Information

2424Radiance Direct Vent Gas Heater 20012697from traffic areas such as walkways if it is less than 7’ (2.1 m) high. Refer to Pages 10, 11, Figures 11,

Seite 18 - 4/20/01 djt

25Radiance Direct Vent Gas Heater20012697If the wall is brick or concrete, and contains no com-bustible material, a 7” (178 mm) round penetration hole

Seite 19 - 12/6/99 djt

2626Radiance Direct Vent Gas Heater 20012697Minimum HeightAbove RoofST934minimum height6/07 Minimum Roof Pitch Height Flat to 7/12 1’0” Over

Seite 20

27Radiance Direct Vent Gas Heater20012697Rear LogLG488Figure 482. Install the rear log by plac-ing it on the ember bed toward the ba

Seite 21 - Vent System

2828Radiance Direct Vent Gas Heater 20012697Figure 51Left Cross LogRear LogRight Cross LogFront Right LogFront Left LogEmber BedLG490

Seite 22 - 

29Radiance Direct Vent Gas Heater20012697Install ON/OFF SwitchThe switch assembly parts are found in the parts bag.1. Attach switch assembly to left

Seite 23 - 

3Radiance Direct Vent Gas Heater20012697The Radiance Direct Vent Room Heater, Model Nos. RADVTCB, RADVTEB, RADVTMB, RADVTBS, RADVTCH, RADVTVG, RADVTB

Seite 24 - 

3030Radiance Direct Vent Gas Heater 20012697ST477Stardancepilot location10/4/00Fig. 54 Pilot Assembly location.ST476Pilot As-semblyFlame & Tempe

Seite 25 - 

31Radiance Direct Vent Gas Heater200126973. Open control access panel.4. Push in gas control knob slightly and turn clock-wise to “OFF”. Do not

Seite 26 - Radiance

3232Radiance Direct Vent Gas Heater 20012697Troubleshooting the Gas Control System (RADVT Series)NOTE: Before trouble shooting the gas control system

Seite 27 - 

33Radiance Direct Vent Gas Heater20012697Instructions for Comfort Control ValveRADVTC SeriesThe Comfort Control valve allows remote control of tempera

Seite 28 - Figure 51

3434Radiance Direct Vent Gas Heater 20012697Auto ModeIn the AUTO mode, the room temperature, set tem-perature, flame and fan levels will be shown. AUTO

Seite 29 - Operation

35Radiance Direct Vent Gas Heater20012697Light pilot burnerSet manual switch to local or remoteRelease pilotstat knob.Turn pilotstat knob from PILOT t

Seite 30 - 6/07 djt

3636Radiance Direct Vent Gas Heater 20012697If the manual switch is set to REMOTE,press the mode button to display AUTO on the transmitter. Does the t

Seite 31 - Lighting Instructions

37Radiance Direct Vent Gas Heater20012697Conversion PrecautionsBefore proceeding, turn control knob on valve to OFF and turn gas supply OFF. Turn OFF

Seite 32

3838Radiance Direct Vent Gas Heater 200126972. Remove and replace plug on lower right hand side of the valve; Red for LP and Blue for NG. (Page 32, F

Seite 33 - 3/22/00 djt

39Radiance Direct Vent Gas Heater20012697Burner Orifice Conversion1. Remove three (3) 3/8” nuts on bottom side of burner pan. (Fig. 72)2. Carefully r

Seite 34 - 3/24/00 djt

44Radiance Direct Vent Gas Heater 20012697Requirements for the Commonwealth of MassachusettsAll gas fitting and installation of this heater shall only

Seite 35 - Local Path

4040Radiance Direct Vent Gas Heater 20012697Table 3. Air Shutter Adjustment Natural Gas Natural Gas LP Model High Altitude RADVT/RADVC 1/2

Seite 36 - Auto Path

41Radiance Direct Vent Gas Heater20012697MaintenanceYour Radiance Gas Heater will provide years of service with minimal upkeep. The following procedur

Seite 37 - Fuel Conversion Instructions

4242Radiance Direct Vent Gas Heater 20012697Gasket ReplacementThe Radiance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and

Seite 38 - 1/28/00 djt

43Radiance Direct Vent Gas Heater20012697NOTE: IF ANY OF THE ORIGINAL WIRE, AS SUP-PLIED WITH THE APPLIANCE, MUST BE RE-PLACED, IT MUST BE REPLACED WI

Seite 39 - 

4444Radiance Direct Vent Gas Heater 20012697101a4014167424512697RADVT/RADVTC parts6/07 djt37a,b,c47LOCALREMOTEON•PILOTOFF•LED6781526a,b27a27b27c293028

Seite 40

45Radiance Direct Vent Gas Heater20012697Radiance Direct Vent Gas Heater (continued)Models: RADVT Series: RADVTCB, RADVTEB, RADVTMB, RADVTBS, RADVTCH,

Seite 41 - Maintenance

4646Radiance Direct Vent Gas Heater 20012697Fuel Conversion KitsConversion Kit, NG to LP - RADVTC Kit 20012900Conversion Kit, NG to LP - RADVT Kit 2

Seite 42 - Check the Gas Flame Regularly

47Radiance Direct Vent Gas Heater20012697Radiance Direct Vent Gas Heater (continued)Models: RADVT Series: RADVTCB, RADVTEB, RADVTMB, RADVTBS, RADVTCH,

Seite 43 - 1/11/00 djt

4848Radiance Direct Vent Gas Heater 20012697Optional AccessoriesFan KitsFK26 FanThe FK26 fan helps distribute heated air from within the firebox out in

Seite 44 - RADVTCCG, RADVTCSG

49Radiance Direct Vent Gas Heater20012697

Seite 45

5Radiance Direct Vent Gas Heater2001269729"(758 mm)31"(787 mm)7" Outer Dia.(178 mm)Flue CollarLC4"(120 mm)14"(378 mm

Seite 46 - Fuel Conversion Kits

5050Radiance Direct Vent Gas Heater 20012697

Seite 47

51Radiance Direct Vent Gas Heater20012697LIMITED LIFETIME WARRANTY CFM Corporation (hereinafter referred to as CFM) warrants that all cast iron parts

Seite 48 - Optional Accessories

2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.comCFM Corporation

Seite 49

66Radiance Direct Vent Gas Heater 20012697Installation RequirementsThe installation must conform with local codes or, in the absence of local codes, w

Seite 50

7Radiance Direct Vent Gas Heater20012697Parallel Installation: Minimum Clearance and Flue CenterlineFig. 3 Parallel installation, minimum back and si

Seite 51 - LIMITED LIFETIME WARRANTY

88Radiance Direct Vent Gas Heater 20012697Gas Specifications Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/h RADVT Serie

Seite 52 - CFM Corporation

9Radiance Direct Vent Gas Heater20012697Vertical TerminationA vertical vent system must terminate no less than 8’ (2.44 m) and no more than 40’ (12 m)

Kommentare zu diesen Handbüchern

Keine Kommentare