Vermont Castings Radiance
Tested and listed to
ANSI Z21.11.2b-1998, Unvented Heaters
WARNING: Improper installa-
tion, adjustment, alteration,
service or maintenance can cause
injury or property damage. Refer
to this manual for correct installa-
tion and operational procedures.
For assistance or additional infor-
mation consult a qualified
installer, service agency, or the
gas supplier.
Installation and service must be
performed by a qualified in-
staller, service agency or the gas
supplier.
Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or
any other appliance.
This is an unvented gas-fired heater. It
uses air (Oxygen) from the room
which it is installed. Provisions for
adequate combustion and ventilation
air must be provided.
Radiance
Vent Free Gas Heater
Model RUVS40
3000-0456c/1000
INSTALLER / CONSUMER
SAFETY INFORMATION
WARNING: If the information in
this manual is not followed ex-
actly, a fire or explosion may
result causing property damage,
personal injury or loss of life.
Please read this manual before
installing and using appliance.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency or the gas suppler.
WHAT TO DO IF YOU SMELL GAS
Shut off the gas supply.
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Homeowners Installation
and Operating Manual
INSTALLER: DO NOT DISCARD THIS MANUAL -
LEAVE FOR HOMEOWNER
RADIANCE
0456
Seitenansicht 0
1 2 3 4 5 6 ... 23 24

Inhaltsverzeichnis

Seite 1 - Radiance

1Vermont Castings RadianceTested and listed toANSI Z21.11.2b-1998, Unvented HeatersWARNING: Improper installa-tion, adjustment, alteration,service or

Seite 2 - Table of Contents

10Vermont Castings RadianceInstall Optional Fan, #2767/FK26Install the fan kit before the stove is connected to thegas line.The fan consists of a blow

Seite 3 - Specifications

11Vermont Castings Radiance5. Resecure the Rear Shroud panels.• Reinstall and tighten the two sheet metal screws(D, Fig. 10) that secure the inner an

Seite 4 - Safety Information

12Vermont Castings RadianceConnect the Gas LineGas connection should be made in accordance with thecurrent edition of the National Fuel Gas Code, ANSI

Seite 5 - General Information

13Vermont Castings RadianceInstall the LogsInstall the logs in sequence as shown below. The logset includes six sections: the rear log, left and right

Seite 6 - Installation Requirements

14Vermont Castings Radiance4. Loosely sprinkle the lava rocks (#6) directly on topof the burner, between the front and middle logs. Donot place any em

Seite 7

15Vermont Castings RadianceOperationYour First FireRead these instructions carefully and familiarizeyourself with the burner controls of this heater.T

Seite 8 - Clearance Requirements

16Vermont Castings Radiance1. STOP! Read the safety information above on this panel.2. If applicable, turn thermostat to lowest setting or set burn

Seite 9 - Assembly

17Vermont Castings RadianceTrouble-WarningTurn OFF heater and allow to cool completelybefore servicing.ConditionNo spark at Pilot when Ignitor isopera

Seite 10

18Vermont Castings RadianceTroubleshooting (continued)ConditionPilot lights but Main Burner does notMain Burner shuts off and Pilot flamegoes out whil

Seite 11 - RHEOSTAT

19Vermont Castings RadianceMaintenanceYour Radiance Vent Free heater will provide years ofservice with minimal upkeep. The following procedureswill he

Seite 12 - Connect the Gas Line

2Vermont Castings RadianceATTENTION CONSUMER:In order to ensure safe and effectiveinstallation, this unit must be installed only bya qualified agency,

Seite 13

20Vermont Castings RadianceCatalytic CombustorThe combustor should be cleaned annually to ensureoptimal performance. Follow the procedure below.Tools

Seite 14 - Complete the Installation

21Vermont Castings RadianceItem/Model Number Part NumberRadiance Vent Free Gas Heater RUVS40Item/Model Number Part Number24320181960605452525556555653

Seite 15 - Operation

22Vermont Castings Radiance21. Wire Clip 120861822. Wire Tie,Wire Harness/Rear Shroud 120150423. Wire Harness,Burner / Thermostat 160191324. Wire Harn

Seite 16 - TO TURN OFF GAS TO APPLIANCE

23Vermont Castings Radiance7. The Vermont Castings, Majestic Products Company shallhave no obligation to enhance or update any unit oncemanufactured.I

Seite 17 - Trouble

24Vermont Castings Radiance© The Vermont Castings, Majestic Products Company410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885www

Seite 18 - Odor During Operation

3Vermont Castings RadianceFuel Type: NG LPManifold Pressure; Min. / Max.: 1.7"/3.5" 5.4"/11.0"Min. Inlet Supply Pressure foradjus

Seite 19 - Maintenance

4Vermont Castings Radiance1. Install only in accordance with National Fuel GasCode, ANSI Z223.1 - latest edition. (Exception:Do not derate this applia

Seite 20 - Replace the combustor module

5Vermont Castings RadianceGeneral InformationVent Free FeaturesThe Radiance RUVS40 is an unvented gas heatingappliance tested and listed to the ANSI s

Seite 21 - Vermont Castings Radiance

6Vermont Castings RadianceInstallation RequirementsTHIS HEATER MUST HAVE FRESH AIR FORPROPER OPERATION. IF NOT, POOR FUELCOMBUSTION COULD RESULT. READ

Seite 22 - RUVS40 (Continued)

7Vermont Castings Radiance3. Add the BTU/Hr ratings of all fuel-burning appli-ances installed in the same space, including thefollowing:Gas Water Hea

Seite 23 - Warranty

8Vermont Castings RadianceA: Maximum Alcove Depth... 24" (609mm)B: To Side Wall... 4" (101mm)C