Vermont Castings 1635 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Kamine Vermont Castings 1635 herunter. Vermont Castings 1635 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Homeowners
Installation and
Operating
Manual
For use in the
United States and Canada
SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED,
OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT.
TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS.
FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY OR EVEN DEATH. CONTACT LOCAL BUILDING OFFICIALS
ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN
YOUR AREA.
Do Not Discard This Manual: Retain for Future Use
30001490 10/03 Rev. 3
The Seville
Woodburning Stove
Models 1635, 1636, 1637, 1638
1490
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - The Seville

Homeowner’sInstallation andOperatingManualFor use in theUnited States and CanadaSAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED,OPERATED AN

Seite 2 - Installation Accessories

10Vermont Castings Seville30001490Wall ShieldsWall shields should be constructed of 24 gauge orheavier sheet metal, or another noncombustiblematerial

Seite 3 - Seville, Model 1635

11Vermont Castings Seville30001490Fig. 15 Parallel installation, vertical chimney connector, twowall shields.1(25mm)1(25mm)40(1016mm)40(1016mm)36(914

Seite 4 - Installation

12Vermont Castings Seville30001490Seville 1635 Clearance ChartUse the chart below together with the diagrams on the next page to determine the minimum

Seite 5

13Vermont Castings Seville30001490Alcove InstallationsThe Seville is approved for installation into an alcoveconstructed to maintain the clearances di

Seite 6

14Vermont Castings Seville30001490You will need the following tools to assemble the Seville:• 7/16" open end wrench • safety glasses & gloves

Seite 7

15Vermont Castings Seville30001490Install the Fan1. Position the Fan body within the Rear Shroud asshown in Figure 20. The Fan’s upper flange shouldbe

Seite 8

16Vermont Castings Seville30001490Attach the Chimney Connector1. If you have not already done so, remove the OuterTop Plate by simply lifting it off o

Seite 9

17Vermont Castings Seville30001490Air enters the stove through two, unrestricted inletsand is heated while passing through separate channelsbefore bei

Seite 10 - Vermont Castings Seville

18Vermont Castings Seville30001490In newer homes that are well-insulated and weather-tight, poor draft may result from insufficient air in thehouse.

Seite 11

19Vermont Castings Seville30001490The Primary Air Inlet must be open when starting afire or when refueling.Step 1. Open the primary air control fully

Seite 12 - Seville 1635 Clearance Chart

2Vermont Castings Seville30001490IntroductionThank you for choosing a Vermont Castings Seville to meet your heating needs.We're confident you wil

Seite 13

20Vermont Castings Seville30001490Refuel While the Embers Are Still HotReload the Seville while it is still hot and there areplenty of glowing embers

Seite 14 - Assembly

21Vermont Castings Seville30001490Let the fire in the stove go out and allow the stove tocool completely before beginning any maintenanceprocedure.Car

Seite 15

22Vermont Castings Seville30001490Step 7. Press the gasketed part firmly against itsnormal mating surface to seat the gasket evenly in itschannel. C

Seite 16

23Vermont Castings Seville30001490Annual MaintenancePerform a thorough cleaning, inspection and repaireach Spring, at the end of the heating season.•

Seite 17 - Operation

24Vermont Castings Seville30001490Pipe & Chimney LayoutEvery bend in the flue will act as a brake on theexhaust as it flows from the firebox to th

Seite 18

25Vermont Castings Seville30001490You can judge the moisture content of wood by itsappearance and weight or use a commercially avail-able moisture met

Seite 19

26Vermont Castings Seville3000149018192018192018192013142532183130293436353634332626241228439464140431639561112333837447178221591021239a10aVermont Cas

Seite 20

27Vermont Castings Seville30001490Seville 1635 (continued)Item/Model Number Part Number0-05 Notes:1. In this diagram and throughout this manual, &apos

Seite 21 - Maintenance

28Vermont Castings Seville30001490©Vermont Castings, Majestic Products4. This warranty does not cover a stove repaired bysomeone other than a Vermont

Seite 22 - The Chimney System

3Vermont Castings Seville30001490SpecificationsSeville, Model 1635Maximum heat output... 30,000 Btu’s/hr.1Area heated...

Seite 23 - Draft Management

4Vermont Castings Seville30001490ChimneysYour stove must be connected either to a soundmasonry chimney that meets local codes, to a relinedmasonry ch

Seite 24

5Vermont Castings Seville30001490Masonry Chimneys, cont'd.• Unused openings in an existing masonry chimneymust be sealed with masonry to the thic

Seite 25

6Vermont Castings Seville30001490Double-wall Chimney ConnectorsThe Seville is approved for installation in the U.S. andCanada with double-wall chimney

Seite 26 - Seville Woodburning Stove

7Vermont Castings Seville30001490Connection Above the FireplaceIn this installation, the chimney connector enters thefireplace flue though a thimble l

Seite 27 - Seville 1635 (continued)

8Vermont Castings Seville30001490• Placing a chimney connector pipe inside a sectionof 9" (229mm) diameter, solid-insulated, factory-builtchimney

Seite 28 - Warranty

9Vermont Castings Seville30001490Floor ProtectionA tremendous amount of heat radiates from thebottom plate of your Madison. The floor area directlyun

Kommentare zu diesen Handbüchern